Punch Metal is another widely used product in two-skinned facades, which, by casting shadows on the surface of the bookcase, in addition to creating a special character for each building, creates significant benefits in terms of saving facilities for the project.
With its special expertise in this field and the necessary equipment, EcoArc has gained sufficient knowledge and experience in the past years in various fields of production and structural calculations and installation of this material.
What material is punch metal?
The use of iron and aluminum to create metal punch surfaces is common. Usually, iron with a thickness of 2 to 2.5 mm and dimensions of 1000 × 1800 mm uses suitable surfaces, and also the use of aluminum with a thickness of 3 mm has been done according to the structural calculations and wind pressure in the previous eco-project projects.
The main factor in determining the type of material and thickness and the proposed dimensions of the technical and engineering unit of EcoArc for material punch metal depends a lot on the design pattern of the designer. Also, the installation location is determined by the required height codes and project conditions.
Metal punch installation location
Due to its structure and semi-transparent state, the metal punch has special advantages for both false ceilings and building facades.
In the facade of the building, especially in the south facade with the intensity of the sun of Iran, it is possible to open an account to be installed on the glass parts as a suitable radiant option. As far as possible, depending on the type of pattern used, Reduce radiation to the inside of the building.
But if there is a wall behind it and there is no glass facade, it will have easier connections and installation, and you can create beautiful visual effects for lighting this type of facade at night.
Of course, the type of calculations should be such that the retaining gloves do not cause congestion and visual pollution inside. Which can be a dry ceramic facade or a curtain wall facade. In fact, the greater the distance between the punch facade and the first facade, the greater the anchorage, and the greater the number of structural elements required. A suitable distance of 40 to 60 cm is recommended, and even if the distance is 80 cm, with a little more crowding, the structural elements do not impair the visual vision, but distances greater than 1.5 meters and two meters increase the executive complexity and load. Add more to the main support and more instrument elements will be needed as a result.